100% leak-proof sealing solution for metal threaded joints
- Very high setting speed even at cold temperatues(<0°C)
- Fixed parts can be disassambled by hand tools
Water Regulation Advisory Scheme (WRAS) Approval
Approval of pipe sealant shows that there is no effect on water quality under BS 6920 Standard.
Approval number: 1607539
Deutscher Verein des Gas- und Wasserfaches (DVGW) Approval
Its 100% leak-proof feature in gas and water metallic connections is approved according to DIN EN 751-1.
Approval Number: NG-5146DM0479
Turkish Standards Institution (TSE) Approval
Its 100% leak-proof feature in gas and water metallic connections is approved according to TS EN 751-1.
Approval Number: 14.0.30.4.34.00/TSE-67270
NSF Approval
Approval of pipe sealant shows that there is no effect on water quality under NSF/ANSI 61 Standard.
Approval number: C0429590
Only products that are bearing NSF logo is NSF approved.
Poland National Institute of Public Health (PZH) Approval
Approval of pipe sealant shows that there is no effect on public health under PZH Hygenic Standards.
Approval number: BK/W/0511/01/2019
Water Regulation Advisory Scheme (WRAS) Approval
Approval of pipe sealant shows that there is no effect on water quality under BS 6920 Standard.
Approval number: 1607539
Deutscher Verein des Gas- und Wasserfaches (DVGW) Approval
Its 100% leak-proof feature in gas and water metallic connections is approved according to DIN EN 751-1.
Approval Number: NG-5146DM0479
Turkish Standards Institution (TSE) Approval
Its 100% leak-proof feature in gas and water metallic connections is approved according to TS EN 751-1.
Approval Number: 14.0.30.4.34.00/TSE-67270
NSF Approval
Approval of pipe sealant shows that there is no effect on water quality under NSF/ANSI 61 Standard.
Approval number: C0429590
Only products that are bearing NSF logo is NSF approved.
Poland National Institute of Public Health (PZH) Approval
Approval of pipe sealant shows that there is no effect on public health under PZH Hygenic Standards.
Approval number: BK/W/0511/01/2019
100% leak-proof sealing solution for metal threaded joints
- Very high setting speed even at cold temperatues(<0°C)
- Fixed parts can be disassambled by hand tools
Fast setting
Non-dripping
Ensure parts are clean, dry and free from oil and grease.
Applied with a brush or directly from tube.
Apply the adhesive with a 360 turn to leading threads of the male and female fittings.
Use an absorbent tissue paper to wipe off excess jointing compound in the direction of the thread.
Assembly parts and hold on for 24 hours at 22-24°C to ensure full curing of jointing compound.
For disassembly, use hand tools to remove mating parts.
When it is hard to dissemble at room temperature, apply local heat until reaching 250°C and disassemble while hot. Then, remove any residual cured adhesive mechanically and clean parts with a proper solvent, acetone.
NSF, WRAS, DVGW, TSE
10 minutes
Conditions: 22°CBlue
No
>93°C
Method: ASTM D56-05Up to 0.20mm
24 Months
1.030
22°C-50°C / +150°C
7000 - 8000 cPs (@20 rpm)
22°C, Method: ISO 2555, Equipment: Brookfield RVT, spindle 3Inventory Code | Product Code | Packaging | Inner box | Box | Palette |
---|---|---|---|---|---|
11539 | 5543 | 15 ml | 24 | 144 | 8,640 |
11547 | 5543 | 50 ml | 10 | 120 | 4,320 |
12392 | 5543 | 100 ml | 12 | 96 | 1,296 |
11558 | 5543 | 250 ml | 6 | 36 | 1,296 |